Features and benefits
Maximum 220kVA standby power at 230/400v @ 50Hz 1500rpm
High quality and reliable six cylinder 8.822l turbocharged YTO diesel engine
Ideal for business applications
Silent canopy which can stand outside with lockable doors
Automatic changeover (ATS), maintenance free batteries and trickle charger included
Four-way protection system included
H-specification insulation, brushless alternator with AVR provides stable output
Easy to use digital controller with auto and manual start options
All sets undergo a comprehensive testing/pre delivery inspection prior to delivery peace of mind of earlier of one year/1000 hour warranty
Engine
- YTO heavy-duty diesel engine
- Six cylinder, water cooled, turbocharged
- Electronic governor control system
- 24v DC starter and charge alternator
- Replaceable fuel filter, oil filter and dry element air filter
- Cooling radiator and fan
- Fuel connection hoses and manual sump oil drain valve
- Exhaust silencer
- Maintenance free battery including rack and cables
- Jacket water heater (as option)
- YTO engine manual
Alternator
Brushless, single bearing system, four poles
Insulation class H with circuit breaker protection
Standard degree of protection IP21
Self-exciting and self-regulating
AVR SX460 included
Screen protected and drip proof
Stator winding with 2/3 pitch for improved harmonics
Close voltage regulation
Chassis
Steel chassis and anti-vibration pads
Base frame design incorporates an integral fuel tank
The generator can be lifted or carefully pushed/pulled by the base frame
Includes diesel level sensor information to the controller
Canopy
Ventilation parts are designed with modular principles
Weather resistant and lined with sound reducing foam
All metal canopy parts are painted by powder paint
Panel window
Lockable doors on each side
Easy maintenance and operation
Easy lifting and moving
Insulated engine exhaust system
Exterior emergency stop push button
General specifications
- Structure type
- Dimensions Length x Width x Height
- Dry weight
- ATS unit included
- Four-way protection system included
GKY-220
220kVA
- Silent weather resistant enclosure
- 3400mm x 1400mm x 1850mm
- 3000kg
Engine specifications
- Diesel generator model
- Engine make
- Displacement
- Cylinder bore/stroke
- Fuel system
- Cylinders
- Cylinder arrangement
- Engine output power at 1500rpm
- Turbocharged or naturally aspirated
- Cycle
- Combustion system
- Compression ratio
- Fuel tank capacity
- Fuel consumption 100%
- Fuel consumption 75%
- Fuel consumption 50%
- Fuel consumption 25%
- Oil type
- Oil capacity
- Cooling method
- Coolant capacity (including radiator)
- Starter
- Governor system
- Engine speed
GKY-220
220kVA
- YM6H4L
- YTO
- 8.822l
- 120mm x 130mm
- YTO electronic governor
- 6
- Vertical in-line
- 186kW
- Turbocharged
- Four stroke
- Direct injection
- 17.5:1
- 600l
- 38.1 l/h
- 28.6 l/h
- 19 l/h
- 9.5 l/h
- 15W40
- 23l
- Radiator water-cooled
- 40l
- 24v DC
- Electronic
- 1500rpm
Alternator specifications
- Alternator brand
- Standby power output
- Prime power output
- Insulation Class
- Type
- Phase and connection
- AVR
- AVR model
- Voltage regulation
- Voltage
- Rated frequency
- Voltage regulate change
- Phase change rate
- Power factor
- Protection class
- Stator
- Rotor
GKY-220
220kVA
- STRÖMER
- 220kVA
- 200kVA
- H
- Brushless
- Three phase, four wire
- SX440
- ± 1%
- 230/400v
- 50Hz
- ≤ ±10% UN
- ± 1%
- 0.8
- IP21
- 2/3 pitch
- Single bearing
Control system
Control supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows:
Auto mains failure control panel
Smartgen series automatic transfer switch module
HGM7220 electronic controller
Emergency stop push button
Static battery charger
Four-pole electrically and mechanically interlocked ATS
Generating set control module HGM7220 features
- This module is used to monitor a mains supply and automatically start a standby generating set
- Shutdown alarms
- STOP/RESET-MANUAL-AUTO-TEST-START
Metering via LCD display
Generator volts (L-L/L-N); mains volts (L-L/L-N)
Generator amps (L1, L2, L3); generator (kVA and kW)
Generator frequency; generator (cos)
Engine hours run; plant battery (volts)
Engine oil pressure (psi and bar)
Engine speed (rpm)
GSM SMS signal
Engine temperature (˚C)
Automatic shutdown and fault conditions
Under/over speed; fail to start
High engine temperature; fail to stop
Low oil pressure; charge fail
Under/over generator volts; over current
Under/over generator frequency; emergency stop
Under/over mains frequency
Under/over mains voltage
Low/high battery volts
*All ratings are quoted at maximum ratings at sea level and derating will be applicable for altitude and power factor.