GKP-880 ( 800kVA )

Perkins 800kVA 3 Phase Diesel Generator

Watch video

Features and benefits

  • Maximum 880kVA standby power at 230/400v @ 50Hz 1500rpm
  • High quality and reliable six-cylinder 22.921l Perkins diesel engine
  • Leroy Somer or similar alternator
  • Silent canopy which can stand outside with lockable doors
  • Automatic changeover (ATS), maintenance free batteries and trickle charger included
  • H-specification insulation, brushless alternator with AVR provides stable output
  • Easy to use Deepsea 7320 digital controller with auto and manual start options
  • All sets undergo a comprehensive testing/pre delivery inspection prior to delivery peace of mind of earlier of one year/1000 hour warranty
  • Peace of mind of earlier of one year/1000 hour warranty

Engine

  • Perkins diesel engine
  • Six cylinder, water cooled, turbocharged
  • Electronic governor control system
  • 24v DC starter and charge alternator
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Fuel connection hoses and manual sump oil drain valve
  • Exhaust silencer
  • Maintenance free battery including rack and cables
  • Jacket water heater (as option)
  • Perkins engine manual

Alternator

  • Leroy Somer or similar alternator
  • Brushless, single bearing system, four poles
  • Insulation class H with circuit breaker protection
  • Standard degree of protection IP21
  • Self-exciting and self-regulating
  • AVR included
  • Screen protected and drip proof
  • Stator winding with 2/3 pitch for improved harmonics
  • Close voltage regulation

Chassis

  • Steel chassis and anti-vibration pads
  • Base frame design incorporates an integral fuel tank
  • The generator can be lifted or carefully pushed/pulled by the base frame
  • Includes diesel level sensor information to the controller

Canopy

  • Ventilation parts are designed with modular principles
  • Weather resistant and lined with sound reducing foam
  • All metal canopy parts are painted by powder paint
  • Panel window
  • Lockable doors on each side
  • Easy maintenance and operation
  • Easy lifting and moving
  • Insulated engine exhaust system
  • Exterior emergency stop push button
  • General specifications

  • Structure type
  • Dimensions Length x Width x Height
  • Dry weight
  • ATS unit included
  • GKP-880

  • 880kVA

  • Silent weather resistant enclosure
  • 3900mm x 2300mm x 2000mm
  • 7100kg
  • Engine specifications

  • Engine make
  • Diesel generator model
  • Displacement
  • Cylinder bore/stroke
  • Fuel system
  • Cylinders
  • Standby power output @ 1500rpm
  • Base power output @ 1500rpm
  • Fuel tank capacity
  • Fuel consumption standby
  • Fuel consumption prime
  • Fuel consumption 75% prime
  • Fuel consumption 50% prime
  • Oil type
  • Oil capacity
  • Coolant capacity (including radiator)
  • Starter
  • Governor system
  • Engine speed
  • Engine coolant flow
  • Firing order
  • Compression ratio
  • GKP-880

  • 880kVA

  • Perkins
  • 4006-23TAG3A
  • 22.921l
  • 160mm x 190mm
  • Electronic
  • 6
  • 721kW
  • 521kW
  • 1050l
  • 203 l/h
  • 175 l/h
  • 132 l/h
  • 88 l/h
  • 15W40
  • 120l
  • 120l
  • 24v DC
  • Electronic
  • 1500rpm
  • 10 l/sec
  • 1-5-3-6-2-4
  • 13.6:1
  • Alternator specifications

  • Alternator brand
  • Standby power output
  • Prime power output
  • Insulation class
  • Type
  • Phase and connection
  • AVR
  • AVR type
  • Voltage regulation
  • Voltage
  • Rated frequency
  • Voltage regulate change
  • Phase change rate
  • Power factor
  • Protection class
  • Stator
  • Rotor
  • GKP-880

  • 880kVA

  • Leroy Somer or similar alternator
  • 880kVA
  • 800kVA
  • H
  • Brushless
  • Three phase, four wire
  • R450
  • ± 1%
  • 230/400v
  • 50Hz
  • ≤ ±10% UN
  • ± 1%
  • 0,8
  • IP21
  • 2/3 pitch
  • Single bearing

Control system

Control supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows:

Auto mains failure control panel

  • Smartgen or similar series automatic transfer switch module
  • Deepsea 7320 electronic controller
  • Emergency stop push button
  • Static battery charger
  • Four-pole electrically and mechanically interlocked ATS

Generating set control module Deepsea 7320 features

  • This module is used to monitor a mains supply and automatically start a standby generating set
  • Microprocessor based design
  • Monitors engine performance and AC power output
  • LCD and LED alarm indication; GSM SMS input slot (as optional extra)
  • Front panel configuration of timers and alarm trip points
  • Provides signal to change over switch panel
  • Event logging and shutdown alarms
  • Remote communication via RS232 port or RS485 output
  • Easy push button control
  • STOP/RESET-MANUAL-AUTO-TEST-START
  • Operation indicators accessed by the LCD display
  • Scroll push button

Metering via LCD display

  • Generator volts (L-L/L-N); mains volts (L-L/L-N)
  • Generator amps (L1, L2, L3); generator (kVA and kW)
  • Generator frequency; generator (cos)
  • Engine hours run; plant battery (volts)
  • Engine oil pressure (psi and bar)
  • Engine speed (rpm)
  • GSM SMS signal
  • Phase rotation
  • Engine temperature (˚C)

Automatic shutdown and fault conditions

  • Under/over speed; fail to start
  • High engine temperature; fail to stop
  • Low oil pressure; charge fail
  • Under/over generator volts
  • Under/over generator frequency; emergency stop
  • Under/over mains frequency
  • Under/over mains voltage
  • Low/high battery volts

*All ratings are quoted at maximum ratings at sea level and derating will be applicable for altitude and power factor.

The Generator King (Pty) Ltd reserves the right to change generator information without prior notice. Information is double checked to ensure that it is correct, however The Generator King (Pty) Ltd will not be held responsible for clerical  errors. (E&OE)

FREQUENTLY ASKED QUESTIONS

No, the price does not include installation. Each installation is different and requires a different length  cable. Travel time and distance vary.

All installations need to be carried out  by a qualified electrician who needs to issue a valid Certificate of Compliance (COC) for insurance and to validate our warranty.

No, GenKing are the manufacturers of the gensets units and are the largest wholesaler of diesel generators in Sub-Saharan Africa. Any qualified electrician can do the installation and issue the electrical certificate of compliance (COC).

Quoted prices exclude delivery. Delivery can be quoted separately if you supply us with the delivery location. Our sales team will provide a quote on request and provide logistical support.

Yes, our silent generators all include silent canopies and automatic transfer switches (ATS). Delivery and installation are not included as noted above. Accessories and customisations can be included as required, speak to our sales team for more information.

The warranty is 12 Months or 1000 Hours whichever occurs first and is a limited warranty which covers the replacement of defective spare parts but not the labour or travel. Please refer to our standard terms and conditions for more information.

The pricing is subject to change with no prior notice based on availability and the exchange rate. Any publically available pricing is indicative. Written quotes are valid for 7 calendar days and while stocks last.

All ratings are stated at sea level and de-rating will be applicable for both altitude and temperature variations.

It is important to note that a qualified electrician measures how many Amps per phase you will need to draw on site for your running load and your maximum first-step load.

Do not exceed 50% of the rated load of the generator for your first-step load. Do not exceed more than 75% of the rated load for your running load.

It is also important that your genset does not run at below 50% load as this can cause damage to the engine and other parts.

880kVA Generator | 880kVA Diesel Generator | 880kVA Power Generator | 800kVA Generator | 800kVA Diesel Generator | 800kVA Power Generator | 880kVA Three Phase Generator | 800kVA Three Phase Diesel Generator | Perkins Diesel Generator | Perkins 800kVA 3 Phase Diesel Generator