  • Maximum 880kVA standby power at 230/400v @ 50Hz 1500rpm
  • High quality and reliable six-cylinder 22.921l Perkins diesel engine
  • Leroy Somer alternator
  • Silent canopy which can stand outside with lockable doors
  • Automatic changeover (ATS), maintenance free batteries and trickle charger included
  • H-specification insulation, brushless alternator with AVR provides stable output
  • Easy to use Deep Sea 7320 digital controller with auto and manual start options
  • All sets undergo a comprehensive testing/pre delivery inspection prior to delivery peace of mind of earlier of one year/1000 hour warranty
  • Peace of mind of earlier of one year/1000 hour warranty

Engine

  • Perkins diesel engine
  • Six cylinder, water cooled, turbocharged
  • Electronic governor control system
  • 24v DC starter and charge alternator
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Fuel connection hoses and manual sump oil drain valve
  • Exhaust silencer
  • Maintenance free battery including rack and cables
  • Jacket water heater (as option)
  • Perkins engine manual

Alternator

  • Leroy Somer alternator or similar
  • Brushless, single bearing system, four poles
  • Insulation class H with circuit breaker protection
  • Standard degree of protection IP22
  • Self-exciting and self-regulating
  • AVR included
  • Screen protected and drip proof
  • Stator winding with 2/3 pitch for improved harmonics
  • Close voltage regulation

Chassis

  • Steel chassis and anti-vibration pads
  • Base frame design incorporates an integral fuel tank
  • The generator can be lifted or carefully pushed/pulled by the base frame
  • Includes diesel level sensor information to the controller

Canopy

  • Ventilation parts are designed with modular principles
  • Weather resistant and lined with sound reducing foam
  • All metal canopy parts are painted by powder paint
  • Panel window
  • Lockable doors on each side
  • Easy maintenance and operation
  • Easy lifting and moving
  • Insulated engine exhaust system
  • Exterior emergency stop push button
  • General specifications

  • Structure type
  • Dimensions Length x Width x Height
  • Dry weight
  • ATS unit included
  • GKP-880

  • 880kVA

  • Silent weather resistant enclosure
  • 3900mm x 2300mm x 2000mm
  • 7100kg
  • Engine specifications

  • Engine make
  • Diesel generator model
  • Displacement
  • Cylinder bore/stroke
  • Fuel system
  • Cylinders
  • Standby power output @ 1500rpm
  • Base power output @ 1500rpm
  • Fuel tank capacity
  • Fuel consumption standby
  • Fuel consumption prime
  • Fuel consumption 75% prime
  • Fuel consumption 50% prime
  • Oil type
  • Oil capacity
  • Coolant capacity (including radiator)
  • Starter
  • Governor system
  • Engine speed
  • Engine coolant flow
  • Firing order
  • Compression ratio
  • GKP-880

  • 880kVA

  • Perkins
  • 4006-23TAG3A
  • 22.921l
  • 160mm x 190mm
  • Electronic
  • 6
  • 721kW
  • 521kW
  • 1050l
  • 203 l/h
  • 175 l/h
  • 132 l/h
  • 88 l/h
  • 15W40
  • 120l
  • 120l
  • 24v DC
  • Electronic
  • 1500rpm
  • 10 l/sec
  • 1-5-3-6-2-4
  • 13.6:1
  • Alternator specifications

  • Alternator brand
  • Standby power output
  • Prime power output
  • Insulation class
  • Type
  • Phase and connection
  • AVR
  • AVR type
  • Voltage regulation
  • Voltage
  • Rated frequency
  • Voltage regulate change
  • Phase change rate
  • Power factor
  • Protection class
  • Stator
  • Rotor
  • GKP-880

  • 880kVA

  • Leroy Somer
  • 880kVA
  • 800kVA
  • H
  • Brushless
  • Three phase, four wire
  • R450
  • ± 1%
  • 400/230v
  • 50Hz
  • ≤ ±10% UN
  • ± 1%
  • 0,8
  • IP23
  • 2/3 pitch
  • Single bearing

Control system

Control supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows:

Auto mains failure control panel

  • Smartgen series automatic transfer switch module
  • Deep Sea 7320 electronic controller
  • Emergency stop push button
  • Static battery charger
  • Four-pole electrically and mechanically interlocked ATS

Generating set control module Deep Sea 7320 features

  • This module is used to monitor a mains supply and automatically start a standby generating set
  • Microprocessor based design
  • Monitors engine performance and AC power output
  • LCD and LED alarm indication; GSM SMS input slot (as optional extra)
  • Front panel configuration of timers and alarm trip points
  • Provides signal to change over switch panel
  • Event logging and shutdown alarms
  • Remote communication via RS232 port or RS485 output
  • Easy push button control
  • STOP/RESET-MANUAL-AUTO-TEST-START
  • Operation indicators accessed by the LCD display
  • Scroll push button

Metering via LCD display

  • Generator volts (L-L/L-N); mains volts (L-L/L-N)
  • Generator amps (L1, L2, L3); generator (kVA and kW)
  • Generator frequency; generator (cos)
  • Engine hours run; plant battery (volts)
  • Engine oil pressure (psi and bar)
  • Engine speed (rpm)
  • GSM SMS signal
  • Phase rotation
  • Engine temperature (˚C)

Automatic shutdown and fault conditions

  • Under/over speed; fail to start
  • High engine temperature; fail to stop
  • Low oil pressure; charge fail
  • Under/over generator volts
  • Under/over generator frequency; emergency stop
  • Under/over mains frequency
  • Under/over mains voltage
  • Low/high battery volts

*All ratings are quoted at maximum ratings at sea level and derating will be applicable for altitude and power factor.