GKC-220 ( 200kVA )

Cummins 200kVA 3 Phase Diesel Generator

Watch video

Features and benefits

  • Maximum 220kVA standby power at 230/400v @ 50Hz 1500rpm

  • High quality and reliable six-cylinder 8.3l turbocharged and intercooled Cummins diesel engine

  • Ideal for business applications

  • Silent canopy which can stand outside with lockable doors

  • Automatic changeover (ATS), maintenance free batteries and trickle charger included

  • Four-way protection system included

  • H-specification insulation, brushless alternator with AVR provides stable output

  • Easy to use digital controller with auto and manual start options

  • All sets undergo a comprehensive testing/pre delivery inspection prior to delivery peace of mind of earlier of one year/1000 hour warranty

  • Peace of mind of earlier of one year/1000 hour warranty

Engine

  • Cummins heavy-duty diesel engine
  • Six cylinder, water cooled, turbocharged
  • Electronic governor control system
  • Replaceable wet type cylinder liners
  • 24v DC starter and charge alternator
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Fuel connection hoses and manual sump oil drain valve
  • Exhaust silencer
  • Maintenance free battery including rack and cables
  • Jacket water heater (as option)
  • Cummins engine manual

Alternator

  • Brushless, single bearing system, four poles

  • Insulation class H with circuit breaker protection

  • Standard degree of protection IP22

  • Self-exciting and self-regulating

  • AVR SX460 included

  • Screen protected and drip proof

  • Stator winding with 2/3 pitch for improved harmonicsClose voltage regulation

Chassis

  • Steel chassis and anti-vibration pads

  • Base frame design incorporates an integral fuel tank

  • The generator can be lifted or carefully pushed/pulled by the base frame

  • Includes diesel level sensor information to the controller

Canopy

  • Ventilation parts are designed with modular principles

  • Weather resistant and lined with sound reducing foam

  • All metal canopy parts are painted by powder paint

  • Panel window

  • Lockable doors on each side

  • Easy maintenance and operation

  • Easy lifting and moving

  • Insulated engine exhaust system

  • Exterior emergency stop push button

  • General specifications

  • Structure type
  • Dimensions Length x Width x Height
  • Dry weight
  • ATS unit included
  • Four-way protection system included
  • GKC-220

  • 220kVA

  • Silent weather resistant enclosure
  • 3100mm x 1110mm x 1600mm
  • 2300kg
  • Engine specifications

  • Engine make
  • Diesel generator model
  • Displacement
  • Cylinder bore/stroke
  • Fuel system
  • Cylinders
  • Cylinder arrangement
  • Engine output power
  • Turbocharged or normally aspirated
  • Cycle
  • Combustion system
  • Compression ratio
  • Fuel tank capacity
  • Fuel consumption 100%
  • Fuel consumption 75%
  • Fuel consumption 50%
  • Fuel consumption 25%
  • Oil type
  • Oil capacity
  • Cooling method
  • Coolant capacity (engine only)
  • Starter
  • Governor system
  • Engine speed
  • GKC-220

  • 220kVA

  • Cummins
  • 6CTAA8.3-G2
  • 8.3l
  • 114mm x 135mm
  • BYC PB pump/GAC governor
  • 6
  • Vertical in-line
  • 163kW
  • Turbocharged
  • Four stroke
  • Direct injection
  • 16.5:1
  • 700l
  • 45.4 l/h
  • 34 l/h
  • 23.3 l/h
  • 13.5 l/h
  • 15W40
  • 27.6l
  • Radiator water-cooled
  • 12.6l
  • 24v DC
  • Electronic
  • 1500rpm
  • Alternator specifications

  • Alternator brand
  • Standby power output
  • Prime power output
  • Insulation class
  • Type
  • Phase and connection
  • AVR
  • AVR model
  • Voltage regulation
  • Voltage
  • Rated frequency
  • Voltage regulate change
  • Phase change rate
  • Power factor
  • Protection class
  • Stator
  • Rotor
  • GKC-220

  • 200kVA

  • STRÖMER
  • 220kVA
  • 200kVA
  • H
  • Brushless
  • Three phase, four wire
  • SX460
  • ± 1%
  • 230/400v
  • 50Hz
  • ≤ ±10% UN
  • ± 1%
  • 0,8
  • IP22
  • 2/3 pitch
  • Single bearing

Control system

Control supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows:

Auto mains failure control panel

  • Smartgen series automatic transfer switch module

  • HGM7220 electronic controller

  • Emergency stop push button

  • Static battery charger

  • Four-pole electrically and mechanically interlocked ATS

Generating set control module HGM7220 features

  • This module is used to monitor a mains supply and automatically start a standby generating set
  • Event logging and shutdown alarms
  • STOP/RESET-MANUAL-AUTO-TEST-START

Metering via LCD display

  • Generator volts (L-L/L-N); mains volts (L-L/L-N)

  • Generator amps (L1, L2, L3); generator (kVA and kW)

  • Generator frequency; generator (cos)

  • Engine hours run; plant battery (volts)

  • Engine oil pressure (psi and bar)

  • Engine speed (rpm)

  • GSM SMS signal

  • Engine temperature (˚C)

Automatic shutdown and fault conditions

  • Under/over speed; fail to start
  • High engine temperature; fail to stop
  • Low oil pressure; charge fail
  • Under/over generator volts; over current
  • Under/over generator frequency; emergency stop
  • Under/over mains frequency
  • Under/over mains voltage
  • Low/high battery volts

*All ratings are quoted at maximum ratings at sea level and derating will be applicable for altitude and power factor.

FREQUENTLY ASKED QUESTIONS

No, the price does not include installation. Each installation is different and requires a different length  cable. Travel time and distance vary.

All installations need to be carried out  by a qualified electrician who needs to issue a valid Certificate of Compliance (COC) for insurance and to validate our warranty.

No, GenKing are the manufacturers of the gensets units and are the largest wholesaler of diesel generators in Sub-Saharan Africa. Any qualified electrician can do the installation and issue the electrical certificate of compliance (COC).

Quoted prices exclude delivery. Delivery can be quoted separately if you supply us with the delivery location. Our sales team will provide a quote on request and provide logistical support.

Yes, our silent generators all include silent canopies and automatic transfer switches (ATS). Delivery and installation are not included as noted above. Accessories and customisations can be included as required, speak to our sales team for more information.

The warranty is 12 Months or 1000 Hours whichever occurs first and is a limited warranty which covers the replacement of defective spare parts but not the labour or travel. Please refer to our standard terms and conditions for more information.

The pricing is subject to change with no prior notice based on availability and the exchange rate. Any publically available pricing is indicative. Written quotes are valid for 7 calendar days and while stocks last.

All ratings are stated at sea level and de-rating will be applicable for both altitude and temperature variations.

It is important to note that a qualified electrician measures how many Amps per phase you will need to draw on site for your running load and your maximum first-step load.

Do not exceed 50% of the rated load of the generator for your first-step load. Do not exceed more than 75% of the rated load for your running load.

It is also important that your genset does not run at below 50% load as this can cause damage to the engine and other parts.

220kVA Generator | 220kVA Diesel Generator | 220kVA Power Generator | 200kVA Generator | 200kVA Diesel Generator | 200kVA Power Generator | 220kVA Three Phase Generator | 200kVA Three Phase Diesel Generator | Cummins diesel  Generator

The Generator King (Pty) Ltd reserves the right to change generator information without prior notice. Information is double checked to ensure that it is correct, however The Generator King (Pty) Ltd will not be held responsible for clerical  errors. (E&OE)

  • Automatic change over panels are a convenient method of minimising any disruption caused during a power outage
  • If the mains power falls away the generator controller will immediately start the generator and provide a signal to the change over panel
  • The change over panel will automatically ensure that the power to the site is now provided via the generator with no manual intervention
  • When electricity returns from the mains the controller will signal the automatic change over to return the provision of power to the mains and switch off the generator again
  • The set will now remain in standby mode ready to activate at any moment should a next outage occur
  • The Outback range makes use of a set of electrically and mechanically interlocked contactors to perform the automatic change over
  • The Cummins and Lovol ranges makes use of a electrically and mechanically interlocked transfer switch to perform the automatic change over
  • It is still possible to put the set in manual mode when an automatic change over has been fitted. This is done with the touch of a button on the controller
  • It is important to note that the size of the change over panel must be at least the size of the breaker being supplied with power in amps

 

FREQUENTLY ASKED QUESTIONS

No, the price does not include installation. Each installation is different and requires a different length  cable. Travel time and distance vary.

All installations need to be carried out  by a qualified electrician who needs to issue a valid Certificate of Compliance (COC) for insurance and to validate our warranty.

No, GenKing are the manufacturers of the gensets units and are the largest wholesaler of diesel generators in Sub-Saharan Africa. Any qualified electrician can do the installation and issue the electrical certificate of compliance (COC).

Quoted prices exclude delivery. Delivery can be quoted separately if you supply us with the delivery location. Our sales team will provide a quote on request and provide logistical support.

Yes, our silent generators all include silent canopies and automatic transfer switches (ATS). Delivery and installation are not included as noted above. Accessories and customisations can be included as required, speak to our sales team for more information.

The warranty is 12 Months or 1000 Hours whichever occurs first and is a limited warranty which covers the replacement of defective spare parts but not the labour or travel. Please refer to our standard terms and conditions for more information.

The pricing is subject to change with no prior notice based on availability and the exchange rate. Any publically available pricing is indicative. Written quotes are valid for 7 calendar days and while stocks last.

All ratings are stated at sea level and de-rating will be applicable for both altitude and temperature variations.

It is important to note that a qualified electrician measures how many Amps per phase you will need to draw on site for your running load and your maximum first-step load.

Do not exceed 50% of the rated load of the generator for your first-step load. Do not exceed more than 75% of the rated load for your running load.

It is also important that your genset does not run at below 50% load as this can cause damage to the engine and other parts.

220kVA Generator | 220kVA Diesel Generator | 220kVA Power Generator | 200kVA Generator | 200kVA Diesel Generator | 200kVA Power Generator | 220kVA Three Phase Generator | 200kVA Three Phase Diesel Generator | Cummins diesel  Generator